Model No.: ORC-680E

Multi-functional Anesthesia Machine

Anesthesia Machine
Main body: High-strength engineering plastic rack, light,
Beautiful and corrosion resistant
Scope of application: Adult, child
Gas source: O2: 0.27~0.55MPa N2O: 0.27~0.55MPa
Flow meter: O2: 0.1~1.0L/min 1.1~10L/min
N20: 0.1~1.0L/min 1.1~10L/min
O2, N2O linkage and N2O Stopper: When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.2Mpa, the flow of nitrous oxide would be cut off.
Flow rate of rapid oxygen supply: 25~75L/min
Low oxygen pressure alarm: There will be sound alarm when the oxygen pressure < 0.2MPa.
Vaporizer: It has the function of automatic compensation based on pressure, temperature, and flow
Rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane,
Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by
The customer. And vaporizers that are imported with original packaging are also available.
Respiratory circuit: Working mode: All-close, semi-close, semi-open APL: 0.5~7 kPa
Respiratory Bellows: Bellows for adults, bellows for children Tidal volume range: 0~1500 ml.
Ventilator
Display mode: High-definition 5.7" LCD screen display
Ventilation mode: IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH
Ventilation parameters: Tidal volume: 50~1500 ml
Rate: 2~99 bpm
SIMV rate: 2~20 bpm
I: E: 2: 1~1: 8
Inspiratory trigger pressure: -1.0~2.0 kPa
PEEP: 0~2.0 kPa
Pressure range: 1.0~6.0 kPa
SIGH: 1.5 times the inspiratory time
Parameters for ventilation monitoring:
Tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of
Airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure,
(oxygen concentration)
Security Alarm System:
Oxygen Concentration alarm: Upper limit setting range (50%~100%)
Low limit setting range (15%~50%)
Airway pressure alarm: Upper limit setting range 1.0~6.0 kPa
Low limit setting range 0.4~2.0 kPa
Per-minute ventilation volume alarm: Upper limit setting range 3.0~30L/min
Low limit setting range 1.0~10L/min
Sustained high-pressure alarm: It will give alarm when stress have consistently been higher than 2.5 kPa
Suffocation alarm: It will give sound and light alarm if there is no tidal volume input for 15 seconds
Power alarm
Power: AC 220V&plusmn; 10% 50Hz&plusmn; 1Hz
(UPS, Storage battery)
(Mechanical Arms)
(End-expiratory CO2 monitoring)
*Items within brackets are optional.
bigPhoto
 Mr. Steven Liu

Tel: 86-25-84055220
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Related Products

Company Info

Orchid Medical Instrument Co., Ltd. [China (Mainland)]


Business Type:Manufacturer, Trading Company, Distributor/Wholesaler
Country/Region: China (Mainland)

You May Like:

Product (1)